ZL107695
NEPTUNE SERIES 7000
Mechanical “dia-PUMP”
MODELS 7100 thru 7200
Lansdale, PA. 19446 Tel.: 215-699-8700 FAX: 215-699-0370
www.neptune1.com
A COMPANY
295 DeKalb Pike,
North Wales, PA 19454
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - MODELS 7100 thru 7200

ZL107695 NEPTUNE SERIES 7000 Mechanical “dia-PUMP” MODELS 7100 thru 7200 Lansdale, PA. 1

Strany 2 - SAFETY INSTRUCTIONS:

10 SECTION III NORMAL MAINTENANCE 6.0 MAINTENANCE Under normal conditions, the Mechanical Diaphragm metering pumps should not require any signifi

Strany 3

11 6.3.0 LIQUID HEAD REMOVAL, INSPECTION, AND REINSTALLATION CAUTION If the diaphragm has failed, any process fluid would pass through the bleed h

Strany 4

12MODEL 7100

Strany 5

13 COMMON PARTS TO SERIES 7100-7200 PUMP ITEM NO. DESCRIPTION QTY. PART NO. 1 Gear Box 1 004224 4* Control Stud Holder O-Ring 1 100322 5* Co

Strany 7 - INSTALLATION INSTRUCTIONS

15SECTION IV MOTOR OPERATING CONDITIONS 7.0 The normal temperature rise for standard motors is 40°C above ambient temperature and, thus, it might

Strany 10

18 MSDS MATERIAL SAFETY DATA SHEET IDENTITY: INDUSTRIAL TUFOIL MANUFACTURER: Fluoramics Inc. ADDRESS: 18 Industrial Avenue

Strany 11

19 SECTION 4 - REACTIVITY HAZARD DATA Stability: Stable Conditions to Avoid: Excessive heat - direct flame Incompatability (Materials to Avoid):

Strany 12 - MODEL 7100

2 WARNING LOCKOUTS ARE REQUIRED BEFORE SERVICING THIS EQUIPMENT. SAFETY INSTRUCTIONS: Shut off/Lockout pump Po

Strany 13 - Head Lock Washers

20MAINTENANCE LOG Spare Parts Kit #____________________________________________________________ NEPTUNE CHEMICAL PUMP CO. Tel.: 215-699-8700

Strany 14

3 TABLE OF CONTENTS SECTION PARAGRAPH PAGE I GENERAL DESCRIPTION 4 LIMITED WARRANTY 5 PARTS ORDERING INSTRUCTIONS 6

Strany 15 - SYMPTOMS CAUSES REMEDIES

4 SECTION I GENERAL DESCRIPTION The Neptune Series 7000 Mechanical Diaphragm metering pump is a reliable metering pump of the Low-pressure diaphra

Strany 16

5 SECTION I NEPTUNE CHEMICAL PUMP COMPANY LIMITED WARRANTY All Neptune Pumps are tested at the factory prior to shipment. Each part used in their

Strany 17

6A COMPANYwww.neptune1.comDOVERCHEMICAL PUMP CO.North Wales PA 19454TEL: 215-699-8700 SECTION I PARTS ORDERING INSTRUCTIONS

Strany 18 - SECTION 1 - COMPONENTS

7SECTION II INSTALLATION INSTRUCTIONS 1.0 GENERAL 1.0.1 UNPACKING & INSPECTION When unpacking a pump or chemical feed system, be certain t

Strany 19

8The hydraulic fluid supplied by Neptune is Industrial Tufoil Common sources for hydraulic fluid are: Fluoramics Inc Industrial Tufoil Al

Strany 20 - MAINTENANCE LOG

9 2.0.3 It is recommended that all solution tanks be furnished with a low level cut off switch or low-level alarm and cut off switch to prevent the

Komentáře k této Příručce